NOTE
ELECTROSTATIC SENSITIVE DEVICES:
• Observe precautions for handling.
• Before handling any internal components, discharge static electricity by holding a grounding lug or non-painted surface for three
seconds.
• Wear a grounding wrist strap and stand on a grounded static mat.
• Reduce movement during installation to reduce static buildup.
• Confirm work area is safeguarded.
• Transport components to static-shielded containers.
• Verify that all components, materials, and the installer are reference to a common ground.
The outsides of the ESD bags are not ESD protected.
NOTE
LIFE SAFETY REQUIREMENT: A fail-safe override mechanism must be installed at each card reader exit to allow people to leave the
secure area in case of electromechanical failure.
FOR BURGLAR ALARM INSTALLATIONS:
The TST-100 Touchscreen Terminal is not provided with backup power. An external power supply must be provided with the following
characteristics:
• UL 603 Listed.
• Minimum four hours of standby power.
Tyco/Software House Advanced Power Supply (apS) used in conjunction with the TST-100 Touchscreen Terminal will be sufficient in
meeting the requirement of UL 1076.
When using an external power supply, the supply shall be Class 2 and compliant with EN/IEC 62368.
All Burglar Alarm and Intrusion Zone inputs must be supervised and have Triggers configured to Alarm upon Tamper.