ZED-F9T-Integration Manual
Ensure the group delay variation including active antenna is 10 ns max @ each GNSS system
bandwidth. Note: Inter-signal requirement 50 ns max.
ESD protection on the RF input is mandatory.
Bias-t inductor must be L1 and L2 band frequency selected. 120 nH typical.
Ensure RF trace is tuned for 50 Ω at 1575 MHz to ensure L1 and L2 bandwidth.
4.8.5 Ground pads
Ensure the ground pads under the module are connected to ground.
If a patch type antenna is used, an antenna ground plane with minimum 100 - 150 mm diameter
is required.
4.8.6 Schematic design
For a minimal design with the ZED-F9T GNSS modules, the following functions and pins need to
be considered:
Connect the power supply to VCC and V_BCKP.
V_USB: If USB is used connect V_USB to receiver VCC.
If USB is not used connect V_USB to ground.
Ensure an optimal ground connection to all ground pins of the ZED-F9T GNSS modules.
Choose the required serial communication interfaces (UART, USB, SPI or DDC) and connect the
appropriate pins to your application.
If you need hot or warm start in your application, connect a backup battery to V_BCKP.
Antenna bias is required, see ZED-F9T antenna bias section.
4.8.7 Layout design-in guideline
Is the ZED-F9T placed away from any heat source?
Is the ZED-F9T placed away from any air cooling source?
Is the ZED-F9T shielded by a cover/case to prevent the effects of air currents and rapid
environmental temperature changes?
Is the ZED-F9T placed as recommended in the Layout and Layout Guidance section?
Assure a low serial resistance on the VCC power supply line (choose a line width > 400 um).
Keep the power supply line as short as possible.
Add a ground plane underneath the GNSS module to reduce interference. This is especially
important for the RF input line.
For improved shielding, add as many vias as possible around the micro strip/coplanar
waveguide, around the serial communication lines, underneath the GNSS module, etc.
UBX-19005590 - R01
4 Design Page 71 of 80
Advance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the u-blox ZED-F9T and is the answer not in the manual?

u-blox ZED-F9T Specifications

General IconGeneral
Brandu-blox
ModelZED-F9T
CategoryControl Unit
LanguageEnglish

Related product manuals