45
Condenser Cleaning – Every Three Months
Disconnect electric power to the unit before cleaning the
condenser or the solenoid valve.
Figure 43
Keep the front grille free of dust and lint to allow air to flow to the con-
denser (Figure 43). Clean the condenser coil, located behind the front
grille. Use a brush or vacuum cleaner to remove dirt, lint and other
accumulations from the condenser coil.
To remove and replace the grille for access to the condenser fins
follow this procedure:
Figure 44
1. With a standard blade screwdriver (or 1/4” nutdriver), remove
the grille screw (Figure 44).
2. Remove the control knob by pulling it toward you.
3. Remove the grille.
UL116
REMOVE SCREW
UL005A
!
WARNING
30035 User Manual Body.qxd 1/5/05 8:08 AM Page 45