SARA-G450 - System integration manual
UBX-18046432 - R08 System description Page 30 of 143
C1-Public
SARA-G450 modules UART interface is configured by default in AT command mode: the module waits
for AT command instructions and interprets all the characters received as commands to execute. All
the functionalities supported by SARA-G450 modules can generally be set and configured with AT
commands (see the u-blox AT commands manual [11]).
SARA-G450 modules are designed to operate as a cellular modem, representing the Data
Circuit-terminating Equipment (DCE) as per ITU-T V.24 recommendation [19]. The application
processor connected to the module through the UART interface represents the Data Terminal
Equipment (DTE).
The signal names of SARA-G450 modules UART interface conform to the ITU-T V.24
recommendation [19]: e.g. the TXD line represents the data transmitted by the DTE (application
processor data line output) and received by the DCE (module data line input).
HW flow control handshakes or none flow control are supported by the UART interface and can be set
by AT commands (see u-blox AT commands manual [11], &K, +IFC AT commands).
Hardware flow control is enabled by default.
SARA-G450 modules support one-shot autobauding: the baud-rate automatic detection is performed
once at module start-up, at first AT command received. After detection, the module works at the
detected baud-rate and the baud-rate can only be changed with an AT command.
The following baud-rates can be set by the AT+IPR command (see u-blox AT commands manual [11]):
2400 bit/s
4800 bit/s
9600 bit/s
19200 bit/s
38400 bit/s
57600 bit/s
115200 bit/s
One-shot autobauding is enabled by default.
The one-shot autobauding feature works only with first AT command in capital letters (i.e. “AT”).
The following frame formats can be set by AT+ICF command (see u-blox AT commands manual [11]):
8N1 (8 data bits, no parity, 1 stop bit), default frame configuration
8E1 (8 data bits, even parity, 1 stop bit)
8O1 (8 data bits, odd parity, 1 stop bit)
8N2 (8 data bits, no parity, 2 stop bit)
The automatic frame format recognition is not supported.