Note: It is highly recommended to use a protection diode for inductive
loads as shown below.
2.2.2. Digital Input
The digital input is already equipped with a pull-down resistor. This
means that the reading of the floating input is always low. The
electrical specifications are as follows:
2.2.2.1. Tool Digital Input Usage
The following figure shows the connection with the simple switch.
2.2.3. Tool Analog Input
The tool analog input is a non-differential input. The electrical
specifications are as follows:
Input Voltage in Voltage Mode
Input Current in Current Mode