EasyManua.ls Logo

Ulvac DIS-252 - Maintenance and Inspection; Daily Maintenance and Inspection

Ulvac DIS-252
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-25-
5. Maintenance and inspection
WARNING
Danger of failure and injury
Conduct periodical maintenance and inspection.
If not, it can cause insufficient performance, failure of vacuum pump, and injury.
Conduct periodical
maintenance and
inspection
Danger of burns
Conduct maintenance and inspection only after vacuum pump becomes cool
enough.
Maintenance and inspection soon after vacuum pump stops can cause burn injury.
Be careful about
high temperature
Danger of restart
Be sure to switch off electric source before maintenance or inspection.
Single-phase motor has a thermal protector.
Vacuum pump restarts become cool without warning after vacuum pump.
With a thermal
protector
[Only single-phase
motor]
Danger of electric shock
Be sure to conduct maintenance and inspection after you turn off electric source.
If not, it can cause injury from electric shock or turning object.
Turn off electric
source
Danger of accident, failure and shorter operating lifetime
Ask specialist to perform repairs.
Defective repairs can cause accident, failure or shorter operating lifetime.
Ask specialist to
perform repairs
5.1 Daily maintenance and inspection
Conduct daily the following maintenance and inspection procedures.
Items Contents Measures
Vacuum pump itself
Abnormal sound Ask specialist to repair.
Abnormal vibration Ask specialist to repair.
Abnormal temperature Ask specialist to repair.
Cooling fins are dirty or clogged Blowing air, cleaning
Cooling fan
Fan cover
Abnormal rotation Ask specialist to repair.
Dirty, clogged, damaged
Blowing air, cleaning, ask
specialist to repair.
Air muffler Dirty, clogged Replace
Exhaust valve Dirty, clogged Blowing air, cleaning
Electric source cable Deteriorated Replace

Related product manuals