EasyManuals Logo
Home>Unify>Telephone>Wireless Service Gateway WSG

Unify Wireless Service Gateway WSG Quick Reference Guide

Unify Wireless Service Gateway WSG
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Alarm Functions
Alarm Functions
NOTICE: Alarm function availability depends on the handset variant and the in-
stallation environment. For more information, see the Unify OpenScape WLAN
Phone WL4 User Manual.
Push-Button Alarm
The Push-button can be configured to send an alarm by a long press or a double press. The
alarm is sent to the alarm central that distributes it further, then the handset returns to idle mode.
It is possible to trigger the alarm during other activities such as speaking, editing the settings, or
while the handset is locked.
Man-down and No-Movement Alarm
The Man-down alarm is triggered if the handset is tilted (default 45°) from vertical position for a
predefined period of time (by default for 7 seconds). The Man-down icon shows that the
alarm is enabled.
The No-movement alarm is triggered if no movement is detected for a predefined period of time
(by default for 30 seconds). The No-movement icon shows that the alarm is enabled.
During the warning phase, the handset gives an audio and a vibrating signal (depending on the
settings) for a predefined period of time (by default 7 seconds). At the same time, the handset
displays the message Man-down warning. Cancel? or No-movement warning. Can-
cel?.
The handset then sends the alarm unless the alarm is cancelled. The handset confirms that the
alarm has been sent by giving a beep and vibrating alert. At the same time, the handset displays
the message Man-down alarm sent or No-movement alarm sent.
The man-down and no-movement alarm functions are inactive under the following conditions:
The handset is placed in a charger.
During calls (depending on the settings) to avoid false alarms if the user tilts the handset or is
motionless during a call.
For a predefined period of time (by default for 10 minutes) if the Mute button is pressed dur-
ing the warning phase.
Activate the Man-down and No-Movement Alarm
1) In the Menu, select Settings > Alarm > Activate alarm.
2) Select the required alarm(s). The corresponding icon(s) appear in the status bar.
Deactivate the Man-down and No-Movement Alarm
1) In the Menu, select Settings > Alarm > Deactivate alarm.
2) Select the alarm(s) to deactivate.
Cancel Man-down and No-Movement Alarm
1) Press any key or the soft key OK to confirm Man-down warning. Cancel? or No-move-
ment warning. Cancel?, which appears on the display during the warning phase.
Delay Man-down and No-Movement Alarm Temporarily
A31003-M2000-U110-01-7619, 29/04/2020
14 OpenScape WLAN Phone WL4/WL4 Plus, Quick Reference Guide

Other manuals for Unify Wireless Service Gateway WSG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify Wireless Service Gateway WSG and is the answer not in the manual?

Unify Wireless Service Gateway WSG Specifications

General IconGeneral
BrandUnify
ModelWireless Service Gateway WSG
CategoryTelephone
LanguageEnglish

Related product manuals