EasyManuals Logo

Unipower UP2210 User Manual

Unipower UP2210
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
UNIPOWER
UP-2210 Hardware installation and configuration manual
11
3.4.1 Server performance
The required server performance depends on which PQ Secure application is being used. Unipower
or our representatives can help you with choosing the right computer/server solution.
Data growth in the database is approximate 0,35 to 0,9 GB per Meter per Month (MM) depending on
configuration. With standard configuration 0,54 GB/MM is a good average. This includes all data,
both statistical and events.
When dimensioning a server for a system, use this figure to estimate hard disk requirements. Assume
a server lifetime 4-5 years.
Meter 1 year 5 years Storage volume
1 Meter 0,32 1,6 GB
10 Meters 3,21 16,05 GB
20 Meters 6,42 32,10 GB
50 Meters 16,05 80,25 GB
100 Meters 32,10 160,50 GB
Figure 4