Loading...
Here * and # are wild characters on the setup sheet.
Qualifier
There are three conditional fields in the Qualifier:
Input ID, Length and Match
Input ID
Format:
IN_ID,ID1, ... ,IDi,
Input ID is required and the original data record must correspond to Input ID of a
formula in order to be processed.
ID1 to IDi are represented by digits. The following Input IDs are available:
0 = Code 39 Full ASCII
1 = Code 39 Standard
2 = EAN 13
3 = EAN 8
4 = UPC A
5 = UPC E
6 = I 2 of 5
7 = Codabar
8 = Code 128
9 = Code 93
10 = S 2 of 5
11 = MSI
19 = UCC/EAN128
28 = All Inputs
There is no limitation on the number of IDs to be defined.
Example:
IN_ID,0,11,
means the original data can be Code 39 or MSI.
Length:
Format:
LEN,Min,Max,
Length field consists of two length parameters: minimum length (Min) and