- 46 -
f. Useadrycottontippedapplicatorandrepeatstepsc,dande.(Note:
usedryswabonly,noalcohol.)
4. Cradle connector:
a. Remove the DC power cable from the cradle.
b. Dip the cotton portion of a cotton-tipped applicator in isopropyl alcohol.
c. Rub the cotton portion of the cotton-tipped applicator along the pins of
the connector. Slowly move the applicator back-and-forth from one side
of the connector to the other. Do not let any cotton residue remain on the
connector.
d. Rub all sides of the connector with the cotton-lipped applicator.
e. Spray compressed air in the connector area by pointing the tube/
nozzleabout1/2inchawayfromtthesurface.(Caution:Whenusing
compressed air, always wear eye protection, do riot point nozzle at
yourself and others make sure the nozzle or tube is pointing away from
yourface:andreadwarninglabeloncompressedairproduct.)
f. Remove any lint left by the cotton-tipped applicator.
g. If grease and other dirt are found on other areas of the cradle, use a lint
free cloth and isopropyl alcohol to remove.
h. Allowatleast10to30minutes(dependingonambienttemperatureand
humidity)fortheisopropylalcoholtoairdrybeforeapplyingpowerto
cradle.
Note on drying time: If the temperature is low and humidity is high, longer
drying time is required. Warm temperature and dry humidity require less drying
time.