WF26 EL1 or EG1/
EG2 valve
NO
Replace the power
board
Test 1
EL1 does not close or
EG1/EG2 do not open
YES
YES
Replace the power
board
Replace the EL1
valve
Replace the EG1/
EG2 valve
Test 3
NO
Does the alarm
disapear?
YES EndNO
Replace the
pres sure switch
YES
Replace the power
board
EG2 is the most probable
cause of this alarm
Measure with the
mulmeter set to voltage if th e power
board supplies 230 V AC to the connector
of the water solenoid. Do you have
the supplied on the
EG1/EG2?
Measure with the
mulmeter set to voltage if the
power board supplies 230 V AC to the
connector of the water solenoid.
Do you have the supplied
on the EL1?
Test if the pressure
switch opens the circuit with
the mulmeter set to
ohm. Does it open
the circuit?
and run a washing program.