Page #190 background imageLoading...
Page #190 background image

HOOD
YES
Replace the hood
power board
NO
NOYES
NO
Open the tap
YES
NO
Replace the hood
power board
YES
NO
Replace the water
solenoid valve
YES
Replace the hood
power board
WC02 power
board over
temperature
Let the hood
cool down. Is the warning
message still
displayed?
Has the
hood been
installed following
UNOX guidelines?
Is the
water tap
open?
Install the hood
following The installation
manual on ddc-
service.com
Measure with
the multimeter
set to V AC if the power
board provides 230 V AC
to the connector of the
water solenoid valve.
Is the solenoid
power on?
Does the flow of
water cross the solenoid valve?
(Check if you ear the flux of
water out of the
hood drain)