Page 2-9
Operation and Specifications 2.5 - Maintenance
MX15/19
cord (12 guage (1.5 mm
2
) minimum conductor diameter and 50 ft. (15 m) maximum length)
into a properly grounded outlet of proper voltage and frequency.
3. The charger turns on automatically after a short delay. The LED charge indicator will illumi-
nate. After completion of the charge cycle, the LED will blink, indicating that the charger is in
a continuing maintenance mode. DO NOT leave the charger plugged in for more than 48
hours, as permanent damage to the batteries may occur.
NOTE: The battery charger circuit must be used with a GFI (Ground Fault Interrupt) outlet.
DO NOT operate the machine while the charger is plugged in.
060569-004