USR-TCP232-T2 user manual www.usriot.com
Jinan USR IOT Technology Limited www.usriot.com
Diagram 4.6.10-1 impersistent connection Configuration
4.6.11. Clear buffer data
If the TCP have not built, the data that serial received will be placed in the cache, and the T2 serial port can receive
2Kbyte, after the TCP built, you can select is clear the cached data.
The default is not. Under the Httpd client mode or the TCP client mode, open the short connection and this function
has no power.
Diagram 4.6.11-1 clear buffer data Configuration
4.6.12. Restore out time
Restore out time is to make sure the long and stable work of T2, when the net port or network can not receive data
for long time, T2 will restore out the setting time to avoid abnormal conditions affect the connection. Time for restore can
set in the webpage. The normal work time of this function set 60~65535s, default is 3600s. if setting time less than 60s,
default to be 0 and turn off this function. The setting is as fellow: