EasyManua.ls Logo

USR IOT USR-TCP232-T2 - Page 64

USR IOT USR-TCP232-T2
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USR-TCP232-T2 user manual www.usriot.com
Jinan USR IOT Technology Limited www.usriot.com
64
AT+ CLIENTRST <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ CLIENTRST =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: enable TCP Client reset function
OFF: disable TCP Client reset function
E.g.: AT+CLIENTRST =ON
5.3.4.33. AT+ INDEXEN
Function: setting /query index function
Format: query:
AT+ INDEXEN <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ INDEXEN =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: enable index function
OFF: disable index function
E.g.: AT+INDEX=ON
5.3.4.34. AT+ SOCKSL
Function: setting /query short connection function
Format: query:
AT+ SOCKSL <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ SOCKSL =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: enable short connection function
OFF: disable short connection function
E.g.: AT+SOCKSL =ON
5.3.4.35. AT+ SHORTO
Function: setting /query short connection time
Format: query:
AT+ SHORTO <CR>
<CR><LF>+OK=< time ><CR><LF>
setting: