36
TROUBLESHOOTING‐continued
DoorGlasshassootbuildupatafastrateandflameislazywithblacktips.
Theventpipe(includingairintake)maybedirtyorpartiallyblockedrestrictingairflowtotheunit.
Theintakebutterflyvalvemightbesetattoolowposition.(seepage15)
Burnpotholesareblocked.Lettheunitcoolandcleanburnpotandburnpotliner(besuretofollow
instructionsfordisposalofashesfoundonpage29)
Circuitboardmalfunction.Timethefuelfeedlightateachsetting(after thestove hascompletedthe
initial "Start Up" sequence. Check the timing against the timing chart (found below), if the auger
motorrunsconstantlythereisaproblemwiththecircuitboard
Combustion/Exhaust bloweris not operating.Checkthe combustion/exhaustblower isoperating.If
not,bypasstheexhausttemperatureswitch.Ifthemotoroperates,replacetheexhausttemperature
switch.Ifthecombustion/exhaust blowerstilldoesnotwork,apply120voltsdirectlytotheexhaust
blowermotor.Ifthemotorstilldoesnotwork,replacetheexhaustblowermotor.
Poor fuel quality. The type of pellets being used may be of poor quality. If possible, try a different
brandofpellets(refertofueltypeinformationonpage3).
ControlBoardTiming
Heatlevel1
Augeron2seconds Augeroff5seconds
Heatlevel2 Augeron3seconds Augeroff3seconds
Heatlevel3 Augeron5seconds Augeroff3seconds
Heatlevel4 Augeron7seconds Augeroff3seconds
Heatlevel5 Augeron10seconds Augeroff3seconds

Related product manuals