Disconnection of the head-end control leads
and hose lines
The head-end control leads and hose lines are
already demounted when the unit is delivered.
• Disconnect the BREEZE supply line (33/1) and leakage
line (33/2) so that no liquid escapes.
Disconnect the BREEZE supply line (33/1) and leakage
line (33/2) and collect any escaping liquids.
• Remove the left nuts (35/1) and (35/2) on the left
fastening plate (35/3)
• Remove the right nuts (36/1) and (36/2) on the
rightfastening plate (36/3)
Removal of the rear sheet-metal paneling on the stand
• Remove the exhaust air duct (37/2)
• Remove the left cover (37/3)
• Remove the bottom cover (37/4)
• Demount the warm air recirculation unit, removing the
screws all round (38/3) (optional)
• Remove the cover for the servomotor (38/2)
• Disconnect the control lead (38/5) (mains lead) of the
servomotor