CITY2+ FUNCTION TABLE
DISPLAY DATA DESCRIPTION DEFAULT
MEMO
DATA
t.AP1 0.0’’ ÷ 5’.00 Open time gate panel 1 22.5’
t.AP2 0.0" ÷ 5’.00 Open time gate panel 2 22.5’
t.APP 0.0" ÷ 1’.00 Open time pedestrian gate 6.0’
t.Ch1 0.0" ÷ 2’.00 Close time gate panel 1 23.5’
t.Ch2 0.0" ÷ 2’.00 Close time gate panel 2 23.5’
t.ChP 0.0" ÷ 1’.00 Close time pedestrian gate 7.0’
t.C2P 0.5" ÷ 2’.00 Close time gate panel 2 during pedestrian cycle 2.0’
no - Function disabled
r.AP 0.0"÷ 1’.00 Open gate delay 1.0’
r.Ch 0.0" ÷ 1’.00 Close gate delay 3.0’
t.SEr 0.5" ÷ 1’.00 Electric lock activation time 2.0’
no - The lock is not excited (corresponds to a value of 0)
SEr.S Si / no Silent Locking Mode Si
t.ASE 0.0" ÷ 1’.00 Advance lock time 1.0’
t.inv 0.5" ÷ 1’.00 Pressure surge time no
no - Pressure surge disabled (corresponds to a value of 0)
t.PrE 0.5" ÷ 1’.00 Advance Blinking Time 1.0’
no - Advance blinking disabled (corresponds to a value of 0)
Pot1 30 ÷ 100% Power motor 1 100
Pot2 30 ÷ 100% Power motor 2 100
Po.r1 0 ÷ 70% Power motor 1 during slow-down phase 50
Po.r2 0 ÷ 70% Power motor 2 during slow-down phase 50
P.bAt Si / no Maximum motor power during battery operation Si
SPUn Si / no Breakaway Si
rAM 0 ÷ 6 Starting ramp 4
SEn1 0.0A ÷ 14.0A Obstacle Sensor for Motor 1 0.0A
SEn2 0.0A ÷ 14.0A Obstacle Sensor for Motor 2 0.0A
t.rAL 0.5"÷22.5" Slow-down time (b-2) no
no - Slow-down disabled
t.CVE 0.0" ÷ 3.0" Fast close time after slow-down during closure 0.0’
St.AP Start on open PAUS
no - The START command is not received
ChiU - The gate closes
PAUS - The gate goes into pause
St.Ch Start on close StoP
Stop - The gate finishes the cycle
APEr - The gate opens again
St.PA Start on pause ChiU
no - The START command is not received
ChiU - The gate closes
SPAP Pedestrian start on open PAUS
no - The P. START command is not received
ChiU - The gate closes
PAUS - The gate goes into pause
Ch.AU Automatic re-close. no
no - Automatic re-close is activated (corresponds to a value of 0)
0.5"÷ 20.0' - The gate recloses after the set time
Ch.tr Closure after passage no
no - Closure after passage disabled (load Ch.AU)
0.5"÷ 20.0' - The gate recloses after the set time
PA.tr no / Si Pause after passage no