monitoring & parameters vacon • 49
24-hour support +358 (0)201 212 575 • Email: vacon@vacon.com
5
P2.4 Canopen baud rate 3 8 6 14002
3 = 50 kbaud
4 = 100 kbaud
5 = 125 kbaud
6 = 250 kbaud
7 = 500 kbaud
8 = 1000 kbaud
When DeviceNet E7 board has been installed, the comm. parameters are as follows
V2.1 Communication status 14014
Status of Modbus
communication.
Format:
XXXX.Y, X = DeviceNet
msg counter
Y = DeviceNet status
0 = Non-existent or no
bus power
1 = Configuring state
2 = Established
3 = Timeout
P2.2 Output assembly type 20 111 21 14012 20, 21, 23, 25, 101, 111
P2.3 MAC ID 0 63 63 14010
P2.4 Baud rate 1 3 1 14011
1 = 125 kbit/s
2 = 250 kbit/s
3 = 500 kbit/s
P2.5 Input assembly type 70 117 71 14013
70, 71, 73, 75, 107,
117
When ProfidBus E3/E5 board has been installed, the comm. parameters are as follows
V2.1 Communication status 14022
V2.2 Fieldbus protocol status 14023
V2.3 Active protocol 14024
V2.4 Active buad rate 14025
V2.5 Telegram type 14027
P2.6 Operate mode 1 3 1 14021
1 = Profidrive
2 = Bypass
3 = Echo
P2.7 Slave address 2 126 126 14020
When ModbusTCP & ProfinetIO & Ethernet/IP E9 board has been installed,
the comm.Parameters are as follows
V2.1 IP Part1 1 233 14232
current IP Address
Part1
Code Parameter Min Max Default ID Note
Table 23: System parameters