EasyManua.ls Logo

VADDIO EasyTalk - Appendix 2: Serial Command Interface; EasyUSB Mixer;Amp ASCII Commands

VADDIO EasyTalk
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EasyTalk USB Tools
Vaddio EasyTalk USB Solution - Document Number 342-0449 Rev A Page 45 of 48
Appendix 2: EasyUSB Mixer/Amp Serial Commands (ASCII)
The EasyUSB Mixer/Amp has an RS-232 command interface for configuration and real-time control. The
interface can be used interactively with a serial terminal emulator such as AMX or Crestron Control systems. The
DIP Switch 1 must be in disable mode for the EasyUSB Mixer/Amp to function as a Data Terminal Equipment
(DTE) device. The command echo and prompt can be enabled or disabled with the 6121 command. When
enabled, command input to the EasyUSB Mixer/Amp are echoed back, and a ‘>’ prompt character is
automatically output on a carriage return. When the command echo and prompt are disabled, the echo and
prompt characters are suppressed.
For all commands, the termination character is a carriage return (hex 0D). Responses from the EasyUSB
Mixer/Amp will end with a carriage return followed by a line feed (hex 0A).
The Baud rate of the EasyUSB Mixer/Amp is 38400. (However, if in DCE mode for direct connection to Vaddio
Cameras, baud rate will be 9600). The serial format for the EasyUSB Mixer/Amp is:
Stop Bit: 1
Data: 8 bit
Parity: None
Flow: None
The EasyUSB Mixer/Amp protocol is based upon a “Set” and “Get” scheme. Set commands automatically return
an acknowledgement upon execution.
The “Get” command returns a string representing the current value of the queried setting.
“Set” commands return one of three responses:
OK (4100),
Unknown command (4199), or
Bad parameter (4198).
“Get” commands return a response string indicating the command being responded to and the data requested.
The format of a “get” response is a 4-digit response code, a space, and a two-digit hex value. Examples of
command usage are:
Set Command Usage: > 6101 00 <carriage return> (unmute the microphones)
Response: > 4100 00 (Microphone not muted)
Get Command Usage:> 5101 <carriage return> (queries current mute state)
Response: >4101 00 (Microphone not muted)
EasyUSB Mixer/Amp Command Table
Command Argument Function Successful Response
5101 Get mute status (0=mute off, 1=mute on) 4101 bb (b=00 or 01)
5102 Get speaker volume (need range) 4102 vv (vv = volume value)
5103 Get mic volume (need range) 4103 vv (vv = volume value)
6101 0 or 1 Set mute off/on
4100 bb (bb=00 or 01, repeats 6101
argument)
6102 0 or 1 Decrement/increment speaker volume
4100 bb (bb=00 or 01, repeats 6102
argument)
6103 0 or 1 Decrement/increment mic volume
4100 bb (bb=00 or 01, repeats 6103
argument)
6121 0 or 1 Disable/enable serial echo None if arg=0, 4100 01 if arg=1

Table of Contents