Do you have a question about the Vaillant aroTHERM plus and is the answer not in the manual?
Refrigerant | R290 |
---|---|
Energy efficiency class (Heating, 35°C) | A+++ |
Energy efficiency class (Heating, 55°C) | A++ |
Type | Air-to-water |
Heating capacity | 3.0 to 12.0 kW |
COP | up to 5.4 |
Sound pressure level | 35 dB(A) |
Classification of warnings using symbols and signal words for danger severity.
Product definition, application, and usage scope, including age and capability restrictions.
Risk of fire and explosion due to R290 refrigerant leak and flammable atmosphere.
Danger from tampering with safety devices or altering the product or its lines.
Danger of injury or material damage from incorrect or neglected maintenance and repairs.
Risk of material damage if the heating installation is not kept operational during freezing conditions.
Risk of danger to persons and material damage from improper product operation.
Guidelines on observing and storing operating instructions and other applicable documents.
Specifies the product models to which these instructions apply.
Guidance on obtaining additional installation information via smartphone scanning.
Diagram and explanation of a sample heat pump system with monoblock technology.
Defines the product as an outdoor unit of an air-to-water heat pump with monoblock technology.
Explains the heat pump's operation via a closed refrigerant circuit for heating and cooling.
Details how system separation and brine fluid protect the outdoor unit from freezing.
Visual representation of the product's design and components.
Location and content of the product's data plate and serial number.
Information on safety-relevant stickers for R290 refrigerant rules, which must not be removed.
Defines a safety area around the product, specifying exclusions and ignition source restrictions.
Specifies clearance dimensions for ground installation in front of a building wall.
Specifies clearance for ground and flat-roof installations on the premises.
Procedure for switching on the product using disconnectors.
How to use the indoor unit's control for operating the product and system.
Steps to ensure frost protection, including keeping the product switched on and clear of snow.
Procedure for switching off the product via disconnectors.
Instructions for regularly removing debris like leaves and snow from around the product.
Guidance on cleaning the product casing with a damp cloth and mild soap.
Emphasizes annual inspection by a competent person and warns against self-maintenance.
Directs users to the appendix troubleshooting table and advises contacting a professional if measures fail.
Steps for temporary shutdown, including switching off and protecting against frost.
Procedure for permanent decommissioning, requiring a competent person.
Mandates professional disposal of refrigerant by an authorized person.