0020297937_01 aroTHERM plus Installation and maintenance instructions 139
18 Temperature sensor, in front of the compressor
19 Pressure switch
20 Temperature monitor
21 Pressure sensor, in the high-pressure area
22 Electronic expansion valve
23 Temperature sensor, at the evaporator
24 Temperature sensor, behind the condenser
25 Actuation for INVERTER assembly
26 Slot for coding resistor for cooling mode
27 Range for the safety extra-low voltage (SELV)
D Inspection and maintenance work
# Maintenance work Interval
1 Checking the protective zone Annually
129
2 Closing the purging valve During the first service
129
3 Cleaning the product Annually
129
4 Checking the evaporator, fan and condensate discharge Annually
129
5 Checking the refrigerant circuit Annually
129
6 Checking the refrigerant circuit for tightness Annually
130
7 Checking the electrical connections and electrical wires Annually
130
8 Checking the small damping feet for wear Annually after the first 3 years
130
E Technical data
Note
The following performance data is only applicable to new products with clean heat exchangers.
The performance data also covers the noise reduction mode (unit operates with reduced noise emissions).
The data in accordance with EN 14825 is determined using a special test method. You can find information about
this from the manufacturer of the product by stating "EN 14825 test method".
Technical data General
VWL 45/6 A 230V
S3
VWL 55/6 A 230V
S3
VWL 65/6 A 230V
S3
VWL 85/6 A 230V
S3
Width
1,100 mm 1,100 mm 1,100 mm 1,100 mm
Height
765 mm 765 mm 965 mm 965 mm
Depth
450 mm 450 mm 450 mm 450 mm
Weight, with packaging
132 kg 132 kg 150 kg 150 kg
Weight, ready for operation
114 kg 114 kg 128 kg 128 kg
Weight, ready for operation, left-/right-hand
side
38 kg/76 kg 38 kg/76 kg 43 kg/85 kg 43 kg/85 kg
Connection, heating circuit
G 1 1/4 " G 1 1/4 " G 1 1/4 " G 1 1/4 "
Rated voltage
230 V (+10%/-
15%), 50 Hz,
1~/N/PE
230 V (+10%/-
15%), 50 Hz,
1~/N/PE
230 V (+10%/-
15%), 50 Hz,
1~/N/PE
230 V (+10%/-
15%), 50 Hz,
1~/N/PE
Rated power, maximum
3.40 kW 3.40 kW 3.50 kW 3.50 kW
Rated power factor
1.0 1.0 1.0 1.0
Rated current, maximum
14.3 A 14.3 A 15.0 A 15.0 A
In-rush current
14.3 A 14.3 A 15.0 A 15.0 A
IP rating
IP 15 B IP 15 B IP 15 B IP 15 B
Overvoltage category
II II II II
Fan, power consumption
40 W 40 W 80 W 80 W
Fan, quantity
1 1 1 1
Fan, rotational speed, maximum
620 rpm 620 rpm 790 rpm 790 rpm
Fan, air flow, maximum
2,300 m³/h 2,300 m³/h 3,000 m³/h 3,000 m³/h
Heating pump, power consumption
2 50 W 2 50 W 2 50 W 2 50 W

Table of Contents

Other manuals for Vaillant aroTHERM plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant aroTHERM plus and is the answer not in the manual?

Vaillant aroTHERM plus Specifications

General IconGeneral
RefrigerantR290
Energy efficiency class (Heating, 35°C)A+++
Energy efficiency class (Heating, 55°C)A++
TypeAir-to-water
Heating capacity3.0 to 12.0 kW
COPup to 5.4
Sound pressure level35 dB(A)

Related product manuals