INSTALLATION OF THE HORIZONTAL AIR/FLUE DUCT
Observe the maximum flue
lengths as detailed in table on
page 42.
70
1103
70
15
Horizontal air/flue duct
Vaillant Accy No.: 303 209
Contents of the accessory:
Horizontal air/flue duct
87° elbow
2 x 70 mm air duct clamps
1 x internal plastic ring Ø 125
1 x external metal plate
See page 39 et seq. for details of
air/flue duct elements.
Fig. 4.1: Horizontal air/flue conduit
GU_LAZ 82/0
Fig. 4.2: Example of installation with horizontal air/flue duct
IMPORTANT:
The air/flue duct is not concentric
and the air duct has a slope of 1.5°
(if the air flue duct is not cut). The
hole through the wall can therefore
be drilled horizontally with no slope.
Where extensions are used, these
must be installed with a slope at 3° ±
1° (equivalent to 50 mm ± 20 mm
rise per metre length) to ensure that
condensate dows not remain in the
sleeve.
PART 2 CONCENTRIC 80/125
834449_09GB_082006.qxd 10.08.2006 12:20 Seite 47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus 624 and is the answer not in the manual?

Vaillant ecoTEC plus 624 Specifications

General IconGeneral
ModelecoTEC plus 624
CategoryBoiler
Output24 kW
Dimensions (H x W x D)720 x 440 x 338 mm
MountingWall-mounted
FuelNatural Gas
Warranty5 years
TypeCombination
Central Heating Flow Temperature Range30°C to 80°C

Related product manuals