Appendix
0020209591_01 ecoTEC plus Installation and maintenance instructions 39
Appendix
A Installer level – Overview
Setting level Values
Unit Increment, select, explanation
Default
setting
Min. Max.
Installer level →
Enter code 00 99 – 1 (competent person code 17) –
Installer level → List of faults →
F.XX - F.XX¹ Current value
– –
–
Installer level → Test programs →
Gas type check Current value – LPG, natural gas –
Installer level → Test programs → Check programs →
P.00 Purging – – – Yes, No –
P.01 Maximum load – – – Yes, No –
P.02 Minimum load – – – Yes, No –
P.06 Filling mode – – – Yes, No –
Installer level → Test programs → Function menu →
T.01 Internal pump – – – On, Off –
T.02 3-way valve – – – On, Off –
T.03 Fan – – – On, Off –
T.04 Cyl. charging pump – – – On, Off –
T.05 Circulation pump – – – On, Off –
T.06 External pump – – – On, Off –
T.08 Burner – – – On, Off –
Installer level → Test programs → Electronics self-test →
Self-test – – – Yes, No –
Installer level → Appliance config. →
Language – – – Deutsch, English, Français, Italiano, Dansk,
Nederlands, Castellano, Türkce, Magyar,
Pусский, Українськa, Svenska, Norsk, Pol-
ski, Čeština, Hrvatski, Slovenčina, Română,
Slovenščina, Português, Srpski
English
Flow temp. setpoint 30 75 ℃ 1 –
DHW temperature 30 60 ℃ 1
Product with hot water generation or connected
domestic hot water cylinder
–
Comfort mode
– –
– On, Off Off
¹Fault lists are only displayed, and can only be deleted, if faults have occurred.