3. APPLIANCE DATA
*When converted using kit 05347F1.
The appliance information label is on the inner face of the back panel at the lower left
hand side. It is visible when the fascia is removed.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
Efficiency % (Gross)
347 Firelite and Regency 71
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
INSTALLER GUIDE
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 5.6kW (19,100 Btu/h) 5.3kW (18,084 Btu/h)
Input - Min. (Gross) 1.57W (5,357 Btu/h) 2.35kW (8,018 Btu/h)
Burner Test Pressure (Cold)
17.95 + 0.75mbar
(7.2 + 0.3in w.g.)
36.4 ± 0.75 mbar
(14.85 ± 0.3in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector - Upper
(Centre Radiants)
Cat 28 - 185 Size 80
Burner Injector - Lower
(Outer Radiants)
Cat 28 - 185 Size 80
Pilot & Atmosphere Sensing
Device
OPNG9093 OPLPG9222
Ignition
Integral twin spark piezo
(Mounted on gas valve)
Integral twin spark piezo
(Mounted on gas valve)
Aeration Non-adjustable Non-adjustable
© Baxi Heating U.K. Limited 2008.