5.3 Fireguard requirements.
A fireguard complying with BS 8423 should be fitted for the protection of young
children, the elderly, the infirm and pet animals.
5.4 Room considerations.
5.4.1 This appliance has exposed battery and electric motor components. It is not
recommended, therefore, that it be used in rooms which contains a bath, shower or
where steam is regularly present due to the possibility of corrosion or electrical
shorting.
5.4.2 Note that soft wall coverings (e.g. embossed vinyl etc.) are easily affected by
heat. They may therefore, scorch or become discoloured when close to a heating
appliance. Please bear this in mind when installing.
5.4.3 It is advisable that combustible fabrics such as curtains are not fitted above the
fire. If, however, this is unavoidable, the extreme bottom edge of the fabric must be at
least 780mm above the base of the fire.
5.5 Fireplace preparation.
5.5.1 The front face of the fireplace should be reasonably flat over the area covered
by the convection box top and side flange seals to ensure good sealing. These faces
should be made good if necessary. The fireplace floor should be reasonably flat to
ensure that a good seal with the convection box can be made.
5.5.2 A hole 152mm (6in) dia. is required through the wall for the flue unit. The height
of the hole centre is shown in figure 2 and on the wall-fixing template supplied with
the appliance.
5.5.3 Combustible cladding.
Masquerade/Excelsior and Dream models.
If the fire is to be fitted against a wall with
combustible cladding, the cladding must be
removed from the area shown in
figure 3.
5.6 The surround.
The appliance can be fitted to a purpose made
proprietary class “O” 150°C surround. We
recommend that the surround manufacturer is
contacted to confirm compatibility.
Page 13
© GDC Group Ltd. 2014
INSTALLER GUIDE
Figure 3. Area to be free of
combustible cladding.