17.13 To remove the main burner injector.
(See figure 44).
1. Remove the burner (See section 17.12, paragraphs
1-4).
2. Remove the burner clamping screw (See figure 44)
3. Unscrew the injector from the burner
4. Refit in the reverse order.
17.14 To remove the appliance from the fireplace.
1. Remove the burner unit (See section 17.6).
2. If the fire retention is as method 1 remove the fixing
screws.
If the fire retention is as method 2 (See section 9.2 of
installation instructions), slacken the hexagonal
adjusters on the cable retainers and unscrew the thumbscrews to release the cables.
3. Refit as described in the relevant installation sections. Make sure gas soundness,
sealing, spillage test and performance are satisfactory.
Page 41
© GDC Group Ltd. 2013
INSTALLER GUIDE
Figure 44. Main burner