9
V-Module Kit (GV60VM)
Hardware
The GV60VM kit consists of:
• V-Module
• AC power cable
• Receiver connector cable
See "Hardware Requirements" on page 2 for full
details.
Installing the V-Module
See "Wiring Diagram" on page 4 for details.
1. Disconnect power to the appliance.
2. Connect the AC power cable's Molex connector to
the POWER terminal of the V-Module.
3. Plug the power cable into the fi replace's AC recep-
tacle. The receptacle is located inside the fi replace in
the bottom left corner.
4. Connect one end of the V-Module's Receiver termi-
nal cable (white connector) to the MODULE Port on
the Receiver, and the other end to the V-Module.
5. Connect the fan Molex connector (if applicable).
6. Attach Velcro and place the V-Module as close to the
location indicated in the diagram below as possible,
in the back left corner of the bottom of the fi replace,
behind the receiver.
Proceed to Remote Kit (RCK400).
Module cable
(to Receiver, see
Wiring Diagram)
AC Power cable
(to receptacle)
Fan cable
(if applicable)
P2
Note
The V-module should be placed as close to the
Receiver as possible depending on your fi replace.
Note
This Section only applies to 200A fi replaces with
an incompatible V-Module (V2 or earlier), or
those lacking a V-Module entirely. Skip this page if
this does not apply.
P2 Models