5.3 Connecting the cables
5.3.1 Setting the jumpers
There are 3 jumpers inside the front of the reader. Use the jumpers to set the reader to OSDP or Wiegand mode, to set
OSDP Addressing or Wiegand format, and to set the End Of Line (EOL) status for the reader.
1 Set reader to OSDP or Wiegand mode
2 Set OSDP addressing or Wiegand formats
3 Set End Of Line (EOL) status for the reader
* This indicates the bottom of the reader
5.3.1.1 OSDP
The diagrams below show how to position the jumpers to get the desired functions from the terminal blocks. Note that
the EOL is ON for a sole reader or for the last reader on the RS485 bus.
Mullion Reader User Manual Mounting and connecting
© Vanderbilt 2018 13
A-100410
21.06.2018