Installation, Operating & Maintenance Instructions
Series 650, DN 100 – 250 (I.D. 4" - 10")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel ++41 81 771 61 61 Fax ++41 81 771 48 30 Email reception@vat.ch www.vatvalve.com
258550EE
2007-05-11
1/51
Pendulum control & isolation valve
with Logic interface
This manual is valid for the valve ordering number(s):
650 . . - . . GC - . . . . (1 sensor input)
650 . . - . . GE - . . . .
(2 sensor inputs)
650 . . - . . AC - . . . .
(1 sensor input / ±15V SPS)
650 . . - . . AE - . . . .
(2 sensor inputs / ±15V SPS)
650 . . - . . HC - . . . .
(1 sensor input / PFO)
650 . . - . . HE - . . . .
(2 sensor inputs / PFO)
650 . . - . . CC - . . . .
(1 sensor input / ±15V SPS / PFO)
650 . . - . . CE - . . . .
(2 sensor inputs / ±15V SPS / PFO)
SPS = Sensor Power Supply PFO = Power Failure Option
configured with firmware 650P.1D.00
The fabrication number is indicated on each product as per the label
below (or similar):
made in Switzerland
Fabrication No.: patented
. .
650
. .
. . . .
. . . . / . . . .
A
Fabrication number
Explanation of symbols:
Read declaration carefully before you start any other
action!
Keep body parts and objects away from the valve
opening!
Attention!
Hot surfaces; do not touch!
Product is in conformity with EC guidelines!
Loaded springs and/or air cushions are potential
hazards!
Disconnect electrical power and compressed air
lines. Do not touch parts under voltage!
Wear gloves!
Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General
Safety Instructions» carefully before you start any other action!

Questions and Answers

  • C
    carrienolanAug 17, 2025
    How to fix VAT 65048 when remote operation does not work?
    • D
      Dillon JimenezAug 17, 2025
      If remote operation of the VAT Control Unit is not working, it might be because local operation via the service port is active, or the safety mode is engaged (indicated by a 'D' on the display). Ensure you switch to remote operation and that the motor has sufficient power for operation.
  • C
    Cynthia FoxAug 20, 2025
    Why is VAT 65048 PRESSURE CONTROL not optimal?
    • G
      glovercassandraAug 20, 2025
      If the PRESSURE CONTROL of your VAT Control Unit isn't working optimally, ensure that the setup procedure has been completed, and perform LEARN. Also, make sure ZERO was performed before LEARN. If LEARN was interrupted, repeat it with a stable gas flow. Tune the valve for your specific application, and verify that the sensor range is suitable, ensuring the controlled pressure is within 3% and 98% of the sensor's full scale. Use a shielded sensor cable to reduce noise.
  • B
    brett64Aug 22, 2025
    What to do if pressure is not ‘0’ after ZERO PRESSURE CONTROL on VAT 65048?
    • R
      Rebecca MitchellAug 22, 2025
      If the pressure isn't at ‘0’ after performing ZERO PRESSURE CONTROL on your VAT Control Unit, it could be due to several reasons. The sensor voltage might be shifting, or the system might not be pumped to base pressure. It's also possible that the sensor offset voltage exceeds ±1.4V, the safety mode is active (check for 'D' on the display), PRESSURE CONTROL isn't selected (check for 'P' on the display), or LEARN hasn't been done. Wait until the sensor stabilizes before performing ZERO. Ensure the valve is open and the chamber is at base pressure, and provide power to the motor. If necessary, replace the pressure gauge. Select PRESSURE CONTROL mode and perform LEARN.
  • J
    James Holt Jr.Aug 25, 2025
    Why OPEN VALVE does not work on VAT Control Unit?
    • A
      andrew33Aug 26, 2025
      If the OPEN VALVE function isn't working on your VAT Control Unit, it might be because the safety mode is active, indicated by a 'D' on the display. To resolve this, ensure that the motor has sufficient power for operation.
  • S
    Stephen PatelAug 27, 2025
    Why CLOSE VALVE does not work on VAT 65048?
    • B
      Betty PhillipsAug 28, 2025
      If the CLOSE VALVE function isn't working on your VAT Control Unit, it might be because the safety mode is active, indicated by a 'D' on the display. To resolve this, ensure that the motor has sufficient power for operation.
  • J
    joanna49Aug 30, 2025
    What to do if POSITION CONTROL does not work on VAT Control Unit?
    • C
      Courtney ReynoldsAug 30, 2025
      If the POSITION CONTROL on your VAT Control Unit isn't working, it could be due to the safety mode being active (check for 'D' on the display). It may also be that POSITION CONTROL is not selected (check for 'V' on the display). Provide power to the motor to allow for operation. Select POSITION CONTROL mode.
  • Z
    Zoe MorganSep 1, 2025
    Why ZERO does not work on VAT 65048 Control Unit?
    • C
      Carrie HartSep 1, 2025
      If the ZERO function isn't working on your VAT Control Unit, ensure the valve is in the open position (check for 'O' on the display) and that ZERO is enabled. Open the valve and bring the chamber to base pressure before performing ZERO.
  • N
    Nancy ButlerSep 4, 2025
    What does «SR» mean on VAT 65048 Control Unit display?
    • J
      johnbeckerSep 4, 2025
      If the display of your VAT Control Unit shows «SR» (Service Request), it indicates that the valve unit is heavily contaminated or the gate seal is heavily sticking. Clean the valve and/or replace the gate seal.
  • C
    Christy BrownSep 6, 2025
    What does error «E 22» mean on VAT 65048 Control Unit?
    • M
      michelle86Sep 7, 2025
      If the display of your VAT Control Unit shows «E 22» (fatal error - rotation angle of valve plate limited during operation), it means the valve plate is mechanically obstructed. Resolve the obstruction.
  • V
    Victoria RobersonSep 9, 2025
    What does error «E 40» mean on VAT Control Unit?
    • M
      mendezmarySep 9, 2025
      If the display on your VAT Control Unit shows «E 40» (fatal error - motor driver failure detected), replace the control unit.

Summary

Pendulum control & isolation valve with Logic interface

2 Installation

2.2 Installation into the system

Guidance on integrating the valve into the vacuum system, including safety precautions.

2.5 Requirements to sensor connection

2.6 Electrical connection

2.6.2 Power and sensor connection (+24 VDC sensors)

Provides wiring diagrams for connecting power and +24 VDC sensors.

2.6.3 Power and sensor connection (±15 VDC sensors) without optional SPS module

Wiring details for ±15 VDC sensors without an optional SPS module.

2.6.4 Power and sensor connection (±15 VDC sensors) with optional SPS module

Wiring details for ±15 VDC sensors with an optional SPS module.

3 Operation

3.1.1 Local operation

Instructions for operating the valve via a computer using service port and software.

3.1.2 Remote operation

Guidance on operating the valve remotely using digital and analog signals.

3.3 Behavior during power up

3.4 Behavior in case of power failure

3.5 Display information

3.6 Setup procedure

3.9 Position control

3.10 Pressure control

3.10.2 Tuning of control performance

Provides procedures to optimize pressure control performance through parameter adjustments.

3.10.2.1 Gain factor adjustment

Adjusts the gain factor to influence stability and response time for pressure control.

3.10.2.2 Sensor delay adjustment

Adapts sensor delay to improve stability, potentially slowing control response.

3.10.2.3 Setpoint ramp adjustment

Defines the time for pressure changes between setpoints to improve response.

3.10.2.4 Valve speed adjustment

Modifies the valve plate actuating speed for pressure and position control.

3.11 Logic interface

4 Trouble shooting

5 Maintenance & repairs

VAT 65048 Series Specifications