EasyManua.ls Logo

VAT 65040 Series User Manual

Default Icon
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation, Operating & Maintenance Instructions
Series 650, DN 100 – 250 (I.D. 4" - 10")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel ++41 81 771 61 61 Fax ++41 81 771 48 30 Email reception@vat.ch www.vatvalve.com
258550EE
2007-05-11
1/51
Pendulum control & isolation valve
with Logic interface
This manual is valid for the valve ordering number(s):
650 . . - . . GC - . . . . (1 sensor input)
650 . . - . . GE - . . . .
(2 sensor inputs)
650 . . - . . AC - . . . .
(1 sensor input / ±15V SPS)
650 . . - . . AE - . . . .
(2 sensor inputs / ±15V SPS)
650 . . - . . HC - . . . .
(1 sensor input / PFO)
650 . . - . . HE - . . . .
(2 sensor inputs / PFO)
650 . . - . . CC - . . . .
(1 sensor input / ±15V SPS / PFO)
650 . . - . . CE - . . . .
(2 sensor inputs / ±15V SPS / PFO)
SPS = Sensor Power Supply PFO = Power Failure Option
configured with firmware 650P.1D.00
The fabrication number is indicated on each product as per the label
below (or similar):
made in Switzerland
Fabrication No.: patented
. .
650
. .
. . . .
. . . . / . . . .
A
Fabrication number
Explanation of symbols:
Read declaration carefully before you start any other
action!
Keep body parts and objects away from the valve
opening!
Attention!
Hot surfaces; do not touch!
Product is in conformity with EC guidelines!
Loaded springs and/or air cushions are potential
hazards!
Disconnect electrical power and compressed air
lines. Do not touch parts under voltage!
Wear gloves!
Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General
Safety Instructions» carefully before you start any other action!

Questions and Answers:

VAT 65040 Series Specifications

General IconGeneral
BrandVAT
Model65040 Series
CategoryControl Unit
LanguageEnglish

Summary

Use of product

Technical Data

Detailed specifications and parameters of the product.

Installation

System Installation

Guidelines for physically mounting the valve into the vacuum system.

Electrical Connections

Details on connecting power, sensors, and control signals to the valve.

Power & Sensor Connection (+24 VDC)

Wiring diagram for +24VDC sensors and power supply.

Power & Sensor Connection (±15 VDC) without SPS

Wiring for ±15VDC sensors without the optional SPS module.

Power & Sensor Connection (±15 VDC) with SPS

Wiring for ±15VDC sensors with the optional SPS module.

Operation

Safety Mode Explained

Explains the safety mode and its implications for operation and maintenance.

Valve Setup Procedure

Step-by-step guide to configure the valve for pressure or position control.

Zero Calibration

Compensating sensor offset voltage for accurate zero point.

System Learning (LEARN)

Adapting the PID controller to the vacuum system characteristics.

Position Control Mode

How to control the valve's position directly.

Pressure Control Mode

How to set up and perform pressure control using the valve.

Tuning Pressure Control Performance

Procedures for adjusting PID controller parameters for optimal performance.

Gain Factor Adjustment

Adjusting the gain factor for stability and response time.

Maintenance & repairs

Maintenance Procedures

General procedures and recommendations for valve maintenance.

Spare parts and accessories

Warranty

Related product manuals