2.3 LED Display
LED display The CANcaseXL/log has for each channel (Channel1 and Channel2) three LEDs. The
LEDs indicate the direction of the message and any Error frame that occur:
Rx Tx Err Meaning
(( )) - -
Active when messages are being received.
- (( )) -
Active when messages are being sent.
- - (( ))
Active when error events occur on the bus.
Only in Logger Mode:
Blinking LED means that the related channel
is not „on bus“.
(( )) : Blinking or flashing LED.
2.4 Additional features on CANcaseXL log
2.4.1 Operating modes
Operating modes of
CANcaseXL log
The CANcaseXL log supports two operating modes, which are switched by using the
USB connection and power supply respectively:
USB connection Req. ext. voltage supply Mode
Interface /
Logger configuration
optional
yes
yes Logger
no
Interface Mode
Interface Mode In
the CANcaseXL log operates as usual CAN/LIN interface between
a PC and the bus. Messages can be received and sent over both channels with
suitable tools equal to the CANcaseXL.
Logger Mode The
Logger Mode enables the PC independent usage of the CANcaseXL log and
allows the logging of CAN and LIN events. For this purpose the CANcaseXL log must
be unplugged from the USB connector of the PC. The voltage supply is done
externally by the Binder connector.
Note: Logger Mode configuration For the the additional tool XL log Config is
available (see manual on the installation CD under \Drivers\CANcaseXL
\Tools\XL_log_Config_UsersGuide.pdf
).
Warning: During logging the CANcaseXL log may not be connected to the PC via the
USB cable, since the Logger Mode would otherwise be exited! However the
CANcaseXL log must be in the Interface Mode to configure the
LoggerMode.