Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 98
Function Code: 624 Version 1
Function Type: Set Tank High Water Level Limit
Command Format: Inquire:
Display: <SOH>S624TTII.t <SOH>I624TT
Computer: <SOH>s624TTFFFFFFFF <SOH>i624TT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. II.t - High Water Level Limit, Inches and tenths (Decimal,
Max=05.0)
3. FFFFFFFF - High Water Level Limit, Inches (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I62401
22-05-01 15:09
TANK HIGH WATER LEVEL LIMIT
TANK PRODUCT LABEL INCHES
1 REGULAR UNLEADED 4.9
<ETX>
Typical Response Message, Computer Format:
<SOH>i624TTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - High Water Level Limit, Inches (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum