Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 99
Function Code: 628 Version 1
Function Type: Set Tank Maximum Volume Limit
Command Format: Inquire:
Display: <SOH>S628TTGGGGGG <SOH>I628TT
Computer: <SOH>s628TTFFFFFFFF <SOH>i628TT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. GGGGGG - Maximum Volume Limit, Gallons (Decimal)
3. FFFFFFFF - Maximum Volume Limit, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I62801
22-05-01 15:10
TANK MAXIMUM VOLUME LIMIT
TANK PRODUCT LABEL GALLONS
1 REGULAR UNLEADED 9800
<ETX>
Typical Response Message, Computer Format:
<SOH>i628TTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - Maximum Volume Limit, Gallons (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum

Other manuals for Veeder-Root TLS2