EasyManua.ls Logo

Veeder-Root TLS2 - Page 107

Veeder-Root TLS2
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 104
Function Code: 633 Version 1
Function Type: Set Leak Test Report Type
Command Format: Inquire:
Display: <SOH>S63300f <SOH>I63300
Computer: <SOH>s63300f <SOH>i63300
Typical Response Message, Display Format:
<SOH>
I63301
22-05-01 15:10
LEAK TEST REPORT FORMAT: NORMAL
<ETX>
Typical Response Message, Computer Format:
<SOH>i63300YYMMDDHHmmf&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. f - Leak test Report Type:
0 = Normal
1 = Enhanced
3. && - Data Termination Flag
4. CCCC - Message Checksum

Other manuals for Veeder-Root TLS2

Related product manuals