Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 112
Function Code: 672 Version 5
Function Type: Set Tank Density Low Limit
Command Format: Inquire:
Display: <SOH>S672TTdd.ddd <SOH>I672TT
Computer: <SOH>s672TTFFFFFFFF <SOH>i672TT
Notes:
1. TT - Tank Number (Decimal, 00=all)
2. dd.ddd - Density Low Limit (Decimal)
3. FFFFFFFF - Density Low Limit (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I672TT
04-30-09 9:11 AM
TANK DENSITY LOW LIMIT
TANK PRODUCT LABEL
1 PRODUCT 1 42.139
<ETX>
Typical Response Message, Computer Format:
<SOH>i672TTYYMMDDHHmmTTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00=all)
3. FFFFFFFF - Density Low Limit (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum