Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 111
Function Code: 671 Version 5
Function Type: Set Tank Density High Limit
Command Format: Inquire:
Display: <SOH>S671TTdd.ddd <SOH>I671TT
Computer: <SOH>s671TTFFFFFFFF <SOH>i671TT
Notes:
1. TT - Tank Number (Decimal, 00=all)
2. dd.ddd - Density High Limit (Decimal)
3. FFFFFFFF - Density High Limit (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I671TT
04-30-09 9:11 AM
TANK DENSITY HIGH LIMIT
TANK PRODUCT LABEL
1 PRODUCT 1 56.185
<ETX>
Typical Response Message, Computer Format:
<SOH>i671TTYYMMDDHHmmTTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00=all)
3. FFFFFFFF - Density High Limit (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum