EasyManua.ls Logo

Veeder-Root TLS2 - Page 160

Veeder-Root TLS2
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 157
IN-TANK REPORTS (7.2.2) (Continued)
Code Ver Function
21C 4 Power Outage Delivery Report
21E 4 Inventory Snaphot Volume
21F 4 Manual Shift Inventory Snapshot Report
231 5 In-Tank Full Inventory Report
233 6 Density Offset History Report
234 5 In-Tank Mass / Density Inventory Report 2
235 5 In-Tank Mass / Density Delivery Report 2
I/O DEVICE REPORTS (7.2.3)
Code Ver Function
406 1 Relay Status Report
SETUP FUNCTIONS & REPORTS (7.3)
SYSTEM SETUP (7.3.1)
Code Ver Function
501 1 Set Time of day
502 1 Set Shift Start Time 1, 2, 3, 4
503 1 Set Print Header Line 1, 2, 3, 4
504 1 Set System RS-232 Security Code
50C 1 Set Printer Page Eject Flag
50D 1 Set Print Temperature Compensation Flag
50E 1 Set Temperature Compensation Value
50F 1 Set System Date/Time Display Format
514 1 Set H-Protocol Height/Volume format
517 1 Set System Type & Language Flags
51A 1 Set Enable/Disable Auto Daylight Saving Time
51B 1 Set Start/End Daylight Saving Date and Time
51F 1 Set Euro Protocol Prefix
COMMUNICATIONS SETUP (7.3.2)
Code Ver Function
523 1 Set Receiver Telephone Number
526 1 Set Receiver Retry Number
527 1 Set Receiver Retry Delay Time
52C 1 Set Receiver Auto Dial On Alarms
535 1 Set Modem Hangup Method

Other manuals for Veeder-Root TLS2

Related product manuals