Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 24
Function Code: 118 Version 1
Function Type: Non-Priority Alarm History Report II
Command Format:
Display: <SOH>I11800
Computer: <SOH>i11800
Typical Response Message, Display Format:
<SOH>
I11800
22-05-01 14:56
STATION HEADER 1....
STATION HEADER 2....
STATION HEADER 3....
STATION HEADER 4....
NON PRIORITY ALARM HISTORY REPORT
ID DESCRIPTION ALARM TYPE STATUS DATE TIME REPEAT
T 1 REGULAR UNLEADED PROBE OUT CLEAR 19-03-01 23:36 0
T 1 REGULAR UNLEADED PROBE OUT ALARM 19-03-01 23:36 0
<ETX>
Typical Response Message, Computer Format:
<SOH>i11800YYMMDDHHmmAAccNNTTSSYYMMDDHHmmaaaa...
AAccNNTTSSYYMMDDHHmmaaaa&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. AA - Alarm/Warning Category
See explanation for "AA" in Function i11100
3. cc - Sensor Category
See explanation for "cc" in Function i11100
4. NN - Alarm Type Number
See explanation for "NN" in Function i11100
5. TT - Tank/ Sensor Number
6. SS - Alarm State
01 B Alarm cleared
02 B Alarm occurred
7. YYMMDDHHmm - Date and Time first alarm occurred
8. aaaa - number of times alarm occurred (hex)
9. && - Data Termination Flag
10. CCCC - Message Checksum