Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 48
Function Code: 502 Version 1
Function Type: Set Shift Start Time 1, 2, 3, 4
Command Format: Inquire:
Display: <SOH>S502SSHHmm <SOH>I502SS
Computer: <SOH>s502SSHHmm <SOH>i502SS
Notes:
1. SS - Shift Start time (01, 02, 03, 04)
Typical Response Message, Display Format:
<SOH>
I50201
22-05-01 14:58
SHIFT TIME 1 : DISABLED
<ETX>
Typical Response Message, Computer Format:
<SOH>i502SSYYMMDDHHmmHHmm&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. HHmm - Hour and Minute (EE00 = Disabled)
3. && - Data Termination Flag
4. CCCC - Message Checksum