Function Code: 574 Version 5
Function Type: Set Push Site ID Enable
Command Format: Inquire:
Display: <SOH>S574RRF <SOH>I574RR
Computer: <SOH>s574RRF <SOH>i574RR
Typical Response Message, Display Format:
<SOH>
I57400
JUL 8, 2009 9:02 AM
PUSH SITE ID ENABLE
RCVR PUSH SITE ID
1 ENABLED
<ETX>
Typical Response Message, Computer Format:
<SOH>i57400YYMMDDHHmmRRF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. RR - Receiver Number (Decimal)
3. F - Push Site ID Enable Flag
0 = Disabled
1 = Enabled
4. && - Data Termination Flag
5. CCCC - Message Checksum