Serial Interface Manual
• TLS2 Monitoring Systems
Part No. 577013-767, Revision H 81
Function Code: 604 Version 1
Function Type: Set Tank 1 Point Full Height Volume
Command Format: Inquire:
Display: <SOH>S604TTGGGGGG <SOH>I604TT
Computer: <SOH>s604TTFFFFFFFF <SOH>i604TT
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. GGGGGG - Full Height Volume, Gallons (Decimal)
3. FFFFFFFF - Full Height Volume, Gallons (ASCII Hex IEEE float)
Typical Response Message, Display Format:
<SOH>
I60401
22-05-01 15:07
TANK FULL VOLUME
TANK PRODUCT LABEL GALLONS
1 REGULAR UNLEADED 10000
<ETX>
Typical Response Message, Computer Format:
<SOH>i604TTYYMMDDHHmmTTFFFFFFFF
TTFFFFFFFF&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. FFFFFFFF - Full Height Volume, Gallons (ASCII Hex IEEE float)
4. && - Data Termination Flag
5. CCCC - Message Checksum