51
14 Supplement
VEGAPULS C 21 • Modbus and Levelmaster protocol
58343-EN-200806
Register Number Register Name Data type
Access
Note
108 SV Unit enum16
ro
Unit Code
110 SV oat32
ro
Secondary Variable in Byte Order CDAB
112 TV Unit enum16
ro
Unit Code
114 TV oat32
ro
Third Variable in Byte Order CDAB
116 QV Unit enum16
ro
Unit Code
118 QV oat32
ro
Quarternary Variable in Byte Order CDAB
1300 Status enum8
ro
See Register 100
1302 PV oat32
ro
Primary Variable in Byte Order of Register 3000
1304 SV oat32
ro
Secondary Variable in Byte Order of Register 3000
1306 TV oat32
ro
Third Variable in Byte Order of Register 3000
1308 QV oat32
ro
Quarternary Variable in Byte Order of Register 3000
1400 Status enum8
ro
See Register 100
1402 PV oat32
ro
Primary Variable in Byte Order CDAB
1414 SV oat32
ro
Secondary Variable in Byte Order CDAB
1426 TV oat32
ro
Third Variable in Byte Order CDAB
1438 QV oat32
ro
Quarternary Variable in Byte Order CDAB
2000 Status enum8
ro
See Register 100
2002 PV oat32
ro
Primary Variable in Byte Order ABCD (Big Endian)
2004 SV oat32
ro
Secondary Variable in Byte Order ABCD (Big Endian)
2006 TV oat32
ro
Third Variable in Byte Order ABCD (Big Endian)