110331-01 - 5/20
• Combi Boiler/Water Heater
• Condensing
• Direct Vent
• Gas Fired
Model: PHTM2136C
WARNING
This boiler must only be installed, serviced, or repaired by a qualified heating installer or service technician.
Improper installation, adjustment, alteration, service or maintenance can cause severe personal injury, death,
or substantial property damage. For assistance or additional information, consult a qualified installer, service
agency, or the gas supplier. Read these instruction carefully before installing.
!
Installation, Operating and Service Instructions for
Manual Contents Page
1. Installer Read Before Proceeding .............3
2. Homeowner Read Before Proceeding .........4
3. Specifications ............................5
4. How It Works. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5. Locating Boiler ...........................9
6. Preparing Boiler ..........................13
7. General Venting ..........................16
8. Sidewall Direct Venting ....................23
9. Vertical Direct Venting .....................29
10. Heating System Piping ...................35
11. Domestic Water Piping ....................38
12. Gas Piping .............................41
13. Field Wiring .............................42
14. Condensate Disposal ....................45
15. Start-up and Checkout ..................46
LP Conversion
16. Operation ..............................52
17. Before Leaving Jobsite ...................64
18. Service and Maintenance .................65
19. Troubleshooting .........................69
20. Internal Wiring Diagrams ..................83
21. Service Parts ...........................86
Appendix
A. Combination Refrigeration/Heating System ..92
B. Water Quality and Boiler Additives .........93
C. Special Requirements In Massachusetts ....94
D. Code Required Text ......................96
TO THE INSTALLER:
Affix these instructions adjacent to boiler.
Provide model number and serial number when
seeking information and support.
TO THE HOMEOWNER:
Retain these instructions for future reference.
Contact heating installer or technician for all issues
and support.
VELOCITY LOGO CMYK COLORS
II

Other manuals for Velocity PHANTOM II

Question and Answer IconNeed help?

Do you have a question about the Velocity PHANTOM II and is the answer not in the manual?

Velocity PHANTOM II Specifications

General IconGeneral
BrandVelocity
ModelPHANTOM II
CategoryBoiler
LanguageEnglish

Summary

Installer Read Before Proceeding

Safety Warnings (Asphyxiation, Burn, Electrical)

Covers critical hazards like asphyxiation, burns, and electrical shock.

Boiler Sizing and LWCO Requirements

Guidance on proper boiler sizing and requirements for Low Water Cutoff (LWCO) devices.

User/Homeowner Read Before Proceeding

Boiler Safety and Hazard Awareness

Essential safety information for homeowners regarding boiler hazards and proper use.

Home Protection from Leaks and Freezing

Advises homeowners on protecting their property from potential water leaks and freezing.

Specifications

Ratings, Dimensions, and Venting Specs

Details boiler ratings, physical dimensions, connections, and venting/air sizing requirements.

Electrical, Gas, and Altitude Requirements

Covers electrical needs, gas pressure, altitude limits, and LP gas conversion.

How It Works

Boiler Core Components Overview

Explains the function of key components like the heat exchanger, blower, gas valve, and burner.

Control System, Sensors, and DHW Operation

Details the boiler's control system, sensors, user display, and domestic hot water heating process.

Locating Boiler

Installation Code and Safety Requirements

Covers regulatory compliance, critical safety warnings, placement, mounting, and clearances.

Ventilation Air and Combustion Air Needs

Specifies requirements for ventilation air, combustion air intake, and venting system considerations.

Preparing Boiler

Unpacking and Handling Precautions

Instructions for safely unpacking and handling the boiler, noting its weight and potential damage.

Vent Connector Installation and Fuel Conversion

Steps for installing the vent connector and converting the fuel type, including gas valve adjustments.

Boiler Mounting Procedures

Detailed instructions for securely mounting the boiler to wall structures or studs.

General Venting

Vent Termination Options and Guidelines

Illustrates various sidewall and vertical termination configurations and their clearance requirements.

Vent and Air Sizing Calculations

Explains how to calculate vent and air pipe lengths, including equivalent lengths for fittings and material types.

CPVC/PVC and Polypropylene Venting Requirements

Specifies approved materials, connections, and installation rules for CPVC/PVC and polypropylene venting.

Sidewall Direct Venting

Terminal Location and Wall Penetration Prep

Guidelines for selecting vent terminal location and preparing wall openings for direct venting.

Sidewall Terminal Fittings and Types

Details specific fittings and types for CPVC/PVC and polypropylene sidewall terminations.

Vertical Direct Venting

Terminal Location and Roof Penetration Prep

Requirements for vertical vent terminal placement and preparing roof openings for installation.

Vertical Terminal Fittings and Chase Options

Covers vertical terminal types, fittings, and using B-vent or chimney chases for venting.

Heating System Piping

General Piping Precautions and Safety

Covers essential safety and handling guidelines for all system piping, including hazard awareness.

Required Piping Components and Installation

Details essential components like safety relief valves, pumps, expansion tanks, and their installation.

Domestic Water Piping

DHW Scald Hazards and Tempering Valve Installation

Critical safety information on scald hazards and the mandatory installation of a tempering valve.

Water Quality, Component Protection, and DHW System

Covers water quality requirements, precautions against component damage, and DHW system parts.

Gas Piping

Explosion Hazards and Gas Supply Requirements

Emphasizes explosion risks, proper gas pipe sizing, and compliance with codes for safe gas supply.

Field Wiring

Electrical Shock Hazards and Wiring Precautions

Stresses electrical safety, proper wiring practices, and terminal strip locations.

120VAC and Low Voltage Connection Guidelines

Details requirements for 120VAC power connections and low voltage wiring for controls and sensors.

Condensate Disposal

Asphyxiation Hazard and Condensate Handling

Warns of asphyxiation risk and provides guidance on handling corrosive condensate and disposal methods.

Start-Up and Checkout

System Preparation and Initial Filling

Procedures for cleaning, treating, filling the system with water, and checking freeze protection.

Pre-Startup Checks and LP Conversion

Essential final checks before operation, including gas pressure, combustion tests, and LP conversion steps.

Boiler Operation and Calibration Sequence

Explains the boiler's startup sequence, ignition process, and automatic calibration procedure.

Operation

User Display and Boiler Status Overview

Explains the boiler's control panel display, icons, and how to view operational status.

Adjust Mode Menu and Parameter Configuration

Guides users through accessing and adjusting boiler parameters via the control menu.

Boiler Control System Functions and Protection

Overview of the control system's operation, priority demands, and built-in safety features.

Before Leaving Jobsite

Installation Completion Checklist

A comprehensive checklist to ensure all installation tasks are completed correctly before leaving the jobsite.

Service and Maintenance

Refractory Ceramic Fiber Product Safety Precautions

Critical safety information and handling procedures for components containing refractory ceramic fiber.

Routine Inspections and Boiler Component Servicing

Details monthly and annual inspection tasks, along with procedures for servicing key boiler components.

Troubleshooting

Diagnosing Issues Without Active Fault Codes

Steps for troubleshooting problems when the boiler control does not display specific fault codes.

Troubleshooting with Status and Diagnostic Codes

Guide for interpreting status numbers and diagnostic codes to identify and resolve operational issues.

Internal Wiring Diagrams

Ladder and Schematic Wiring Diagrams

Provides detailed wiring diagrams for understanding the boiler's electrical connections and schematic layout.

Service Parts

Exploded Views and Part Identification

Illustrates various boiler components with key numbers for identifying and ordering replacement parts.

Appendix A Combination Refrigeration/Heating System

System Isolation and Piping Requirements

Guidelines for integrating the boiler with refrigeration systems, ensuring proper isolation and piping.

Appendix B Water Quality and Boiler Additives

System Tightness, Water Quality, and Additives

Emphasizes maintaining system integrity, proper water quality, and correct use of additives to prevent damage.

Freeze Protection and Antifreeze Guidelines

Provides specific recommendations for freeze protection using antifreeze solutions and their proper application.

Appendix C Special Requirements For Side-Wall Vented Appliances In The Commonwealth of Massachusetts

Massachusetts Venting and Safety Requirements

Details specific installation requirements for side-wall vented appliances in Massachusetts, including CO detectors and signage.