4 | 3578 • CB500 VENDOR
The correct vend prices have been programmed into the controller. Refer to
Set Price section in the programming manual supplied with the service
package.
Each price scroll agrees with the vend price.
Each coin tube has at least 12 coins and no tube is filled above the fill level
line. Refer to Coin Tube Fill section in the Programming Manual for information
on using the MDB feature of the control board to track and maintain coin
levels.
The vendor door is closed tightly and locked.
* Not applicable for Model 3578G
Consult local, state, and federal codes and regulations before installation of the
vendor.
To minimize installation time and to avoid service problems due to improper
installation, follow the instructions outlined in this manual.
INITIAL INSTALLATION (Model # 3578 & 3578G)
Read and follow all instructions outlined in the vendor Service Manual. Listed
below are the basic rules or steps that should be followed at the initial installation
of any vending equipment.
1. Carefully plan the route to be taken to the vendor operation site, making sure
that you have adequate manpower and proper equipment to safely handle the
product. Vending machines are relatively large and bulky and may be very
heavy. Improper handling can result in injury.
2. Remove all exterior packing material from the vendor in a manner that does
not damage the finish.
3. Remove the wooden shipping pallet or base. Make sure the leveling screws
for the vendor are in place and functional.
4. FOR Model #3578:
Position the vendor in its place of operation on a flat, smooth surface in such a
way that the vendor’s power cord easily reaches the power outlet or receptacle
(DO NOT USE AN EXTENSION CORD) and check that the door will open fully
without interference.
FOR Model #3578G:
Position the vendor on a Pedestal or Concrete Base or of similar nature so
that the entire Vending machine is located a minimum of 18 inches (450 mm)
above the grade level.
a. Use leg bolt down kit (order separately) to secure the machine to this
18” structure
(or)
WARNING:
This vendor is equipped with a 3 amp circuit breaker to protect the vend
circuit only. The refrigeration system is not on this breaker.
3578G has additional 8 amp circuit braker to protect Vendor