Verint Video Solutions 9
Nextiva S1900e Series User Guide
Performing a Point-to-Point Connection
c
To view video on a monitor in a point-to-point context (as opposed to using a video
management software), you have to create a fixed connection between an S1900e
transmitter and an S1970e receiver. Typically, both devices sit on the same IP subnet as
SConfigurator and have the same VSIP port; to access other devices, refer to the device
discovery section in the SConfigurator User Guide.
For more information about the connection procedure or the video modes, refer to the
“Managing Connections” chapter, in the SConfigurator User Guide.
To perform a point-to-point connection:
1. Start SConfigurator.
2. In the Units tab, discover the desired devices.
The discovered devices appear in the Units box.
3. Select the Connections tab, then click Add.
The Connection Creator window appears.
4. Select a transmitter in the left column and a receiver in the right one.
In the Transmitters column, you have access to the two encoders of each input; the
video stream is the same for both. Stream1 is typically reserved for web viewing,
therefore you should use Stream2 for point-to-point connections.
5. In the Video list, select the desired video mode.
6. To disable I/O data transmission (for example, alarms) between the two selected
devices, clear Forward I/O.
7. To disable serial port data transmission (like PTZ commands), clear Forward Serial
Port Data.
8. To enable audio between the devices, ensure that Enable Audio is checked, then select
the audio mode.
9. Click Connect.
You should now have video on the monitor connected to the receiver.
c