Message from syslogd@host at Sep 12 10:17:53 ...
iscsid:
These messages may appear at different times on the NetBackup Appliance Shell
Menu. They may appear when you are running an iSCSI command, in the middle
of a command output, or even when the console is idle. These messages are
harmless and should be ignored.
About iSCSI alerts
If you have configured alerts for a specific appliance, you can also receive iSCSI
alerts (as applicable). An iSCSI alert is generated in the following situations:
■ An iSCSI session with the target gets disconnected (V-475-108-1000)
■ An iSCSI session with the target storage server is offline (V-475-108-1001)
■ An unsupported Small Form-Factor Pluggable (SFP+) module is detected in a
10 Gb Ethernet/iSCSI card (V-475-107-1000)
The following are sample iSCSI alerts:
An iSCSI session with the target has been disconnected.
Time of event: 2016-09-09 21:34:13 (-07:00)
UMI Event code: V-475-108-1000
Component Type: Connections
Component: <Target IQN> <Portal address> <Interface name>
Status: Disconnected
State: ERROR
Additional information about this error is available at following
link: V-475-108-1000
An iSCSI session with the target storage server is offline.
Time of event: 2016-10-13 21:34:13 (-07:00)
UMI Event code: V-475-108-1001
Component Type: Connections
Component: <Target IQN> <Portal address> <Interface name>
Status: Offline
State: ERROR
Additional information about this error is available at following
link: V-475-108-1001
The SFP+ module that is currently installed in the 10Gb Ethernet/iSCSI
card is not supported.
Time of event: 2016-10-06 18:31:42 (-07:00)
UMI Event code: V-475-107-1000
36Troubleshooting iSCSI issues and some best practices
About iSCSI alerts