6.8. Delay times
6.8.1. PLC Trigger Delay
The following charts are showing the delay times for the different control options:
Normal Mode/External Mode
t = 131 µs. Jitter = 3 µs
Infinite Mode
t = 131 µs. Jitter = 6 µs
The charts show the delay between the PLC Trigger and the actuator voltage. Measuring from
the rising shoulder of the trigger impulse to the beginning of the rising shoulder of the actuator
voltage in dependence of the Jitter.