10
Bollente trutankless® VERO Series Water Heaters www.trutankless.com
Table 3 — DIP Switch Settings Per Model
ELECTRICAL REFERENCE OPTION 1 OPTION 2
DIPSWITCH
CONFIGURATION
Model
Numbers
Maximum
Amperage
Minimum
Breaker
Size
Minimum
Wire
Size
Minimum
Breaker
Size
Minimum
Wire
Size
BR-36 / BC-33 160
2 X 80 Amp
2-Pole
Breakers
4 X #4 Ga.
Copper
BR-28 / BC-25 120
2 X 60 Amp
2-Pole
Breakers
4 X #6 Ga.
Copper
1 X 125 Amp
2-Pole
Breaker
2 X #2 Ga.
Copper
BR-24 / BC-20 100
2 X 50 Amp
2-Pole
Breakers
4 X #6 Ga.
Copper
1 X 100 Amp
2-Pole
Breaker
2 X #2 Ga.
Copper
BR-19/ BC-16 80
2 X 40 Amp
2-Pole
Breakers
4 X #8 Ga.
Copper
1 X 80 Amp
2-Pole
Breaker
2 X #4 Ga.
Copper
BR-14 / BC-12 60
2 X 30 Amp
2-Pole
Breakers
4 X #8 Ga.
Copper
1 X 60 Amp
2-Pole
Breaker
2 X #6 Ga.
Copper