Bollente trutankless® VERO Series Water Heaters www.trutankless.com
P R V
A pressure relief valve is not provided with your VERO BR/BC unit. If local codes require a pressure relief valve to be
installed, simply remove the ¾˝ NPT cap covering the top end-cap pipe nipple and install a ¾” NPT standard female coupling.
is should then be connected to an external drain as per local code requirements.
e trutankless VERO BR/BC unit plumbing connections are now completed.
NOTE: Electrical service connection to the unit must be performed by a licensed contractor in accordance with all applicable
National Electric Safety Codes, and all state/provincial and local electrical codes.
WARNING: This heating apparatus is an electrically powered high voltage and
high current device. It is intended to be installed by a qualied and licensed
contractor only. Failure to install this unit in accordance with all applicable codes
and requirements may result in personal injury or death.
WARNING: Make sure the main power is OFF before proceeding with the electrical
service connection to the system.
NOTE: We strongly recommend the use of copper conductors only.
NOTE: Electrical connections should be made ONLY aer the water system is connected and is tested to be leak-free; all
appropriate ttings are installed; and the required AWG copper wires have been routed to the trutankless VERO BR/BC
Water Heater.
Figure 6 — Wiring Connections: L1, L2 (Red Arrows) & Ground (Orange Arrow)